Railway Cables

Twin Datalink Cable

Application

The cables are used as interconnecting cables for Solid State Interlocking (SSI) systems.

Standards

● BR 1932

Construction

Conductors
Class 1 solid plain copper conductor, 1.27mm nominal diameter.

Insulation
Solid polyethylene.

Inner Sheath
Low density polyethylene.

Moisture Barrier
PE Copolymer coated aluminium tape.

Sheath
Low density polyethylene.

Core Identifi cation
Blue & Red.

Electrical Characteristics at 20℃

Nominal Conductor Diameter
mm
1.27
Nominal Conductor Cross Section
mm²
1.27
Maximum Conductor Resistance
Ω/km
14

Mechanical and Thermal Properties

Minimum Bending Radius: 6×OD
Temperature Range: -25℃ to +85℃ (during operation); -10℃ to +85℃ (during installation)

Dimensions And Weight

Cable Code
No. of pairs
Nominal Sheath
Thickness
mm
Overall Diameter
Min/Max
mm
Nominal Weight
kg/km
1.27mm Conductor, 2.59mm Insulation Wire
RS1932-2Y2Y(L)2Y-1P1.27
1
2.5
12.47/12.8
136